Seria T3 10 – 800 kVA trifazat

FIȘĂ TEHNICĂ:
    Specificații:
    • Model
      ERG T310
      ERG T315
       ERG T320
       ERG T330
       ERG T340
       ERG T360
      Capacity
      10 kVA
      15 kVA
      20 kVA
      30 kVA
      40 kVA
      60 kVA
      Power Watt
      9 kW
      13,5 kW
      18 kW
      27 kW
      36 kW
      54 kW
      Input
      Input Voltage Range 220/380VAC -15% +18% 3P+N+PE Optional 220/380VAC -37% +22% 3P+N+PE
      Input Power Factor At Full Load >0.99
      Input Frequency Range45 – 65 Hz (Selectable)
      RectifierIGBT
      THDi<%3
      Output
      Output Voltage Range220/380VAC, 230/400VAC and 240/415VAC 3 Phase + N ± 1%
      Recovery0% – 100% – 0% Load, Maximum Output Tolerance 5%, 1% Back to Band <40ms
      EfficencyUp to 93%, Eco Mode 98%
      Output Frequency Range50Hz ±0.5% Synchronous With the Network / 50Hz  ±0.01% Battery Mode
      Output THD Lineer Load <%2
      Non-lineer Load <%5
      Crest Factor3:1
      Overload CapacityAt 125% Load 10min, at 150% Load 1min
      Battery
      Quantity (12V DC VRLA)2×31
      Charge Value (C)Nominal 0,1 C, Adjustable
      Battery Power25% of The Device Power
      Internal Battery62 x 7Ah or 9AhNot Available
      Communication
      Communication PortRS232 Standart, RS485 ve SNMP Adapter Option
      Dry ContactOptional
      ProtocolSEC, TELNET
      Standards
      QualityISO 9001 – ISO 14001 – ISO 18001
      PerformanceEN62040 -3 (VFI-SS-111)
      EMC/LVDEN62040 – 2 / EN62040 -1 EN60950
      General
      Running TemperatureFor UPS 0°C~40°C For Battery 0°C~25°C
      Storage TemperatureFor UPS 15°C ~45°C For Batteries -10°C~60°C
      Protection ClassIP20
      ChassisAnti-Static Paint Protection
      Humidity0-95%
      Altitude<1000m, Correction Factor 1. <2000m, Correction Factor >0.92, <3000m; Correction Factor >0.84
      Alerts500  Event  Log
      Paralel OperationParallel Power Increase up to 16pcs.
      EPO (Emergency Power Off) Standard
      Isolation TransformerOptional
      Net Weight (without battery)
      100kg
      100kg
      110kg
      120kg
      125kg
      125kg
      Dimensions (WxDxH)460x805x1190mm
      * under certain conditions
      * 3 Phase in/1 Phase Out Version is Available (10 to 30 kVA)
      Makelsan reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Makelsan products previously or subsequently sold. Makelsan does
      not guarantee the items of the accuracy and completeness.

       

    • Model
      Capacity
      80
      kVA
      100
      kVA
      120
      kVA
      Power Watt
      72 kW
      90
      kW
      96 kW
      Input
      Input Voltage Range 220/380VAC -15% +18% 3P+N+PE Optional 220/380VAC -37% +22% 3P+N+PE
      Input Power Factor At Full Load >0.99
      Input Frequency Range45 – 65 Hz (Selectable)
      RectifierIGBT
      THDi<%3
      Output
      Output Voltage Range220/380VAC, 230/400VAC and 240/415VAC 3 Phase + N ± 1%
      Recovery0% – 100% – 0% Load, Maximum Output Tolerance 5%, 1% Back to Band <40ms
      EfficencyUp to 93%, Eco Mode 98%
      Output Frequency Range50Hz ±0.5% Synchronous With the Network / 50Hz  ±0.01% Battery Mode
      Output THD Lineer Load <%2
      Non-lineer Load <%5
      Crest Factor3:1
      Overload CapacityAt 125% Load 10min, at 150% Load 1min
      Battery
      Quantity (12V DC VRLA)2×31
      Charge Value (C)Nominal 0,1 C, Adjustable
      Battery Power25% of The Device Power
      Internal BatteryNot Available
      Communication
      Communication PortRS232 Standart, RS485 ve SNMP Adapter Option
      Dry ContactOptional
      ProtocolSEC, TELNET
      Standards
      QualityISO 9001 – ISO 14001 – ISO 18001
      PerformanceEN62040 -3 (VFI-SS-111)
      EMC/LVDEN62040 – 2 / EN62040 -1 EN60950
      General
      Running TemperatureFor UPS 0°C~40°C For Battery 0°C~25°C
      Storage TemperatureFor UPS 15°C ~45°C For Batteries -10°C~60°C
      Protection ClassIP20
      ChassisAnti-Static Paint Protection
      Humidity0-95%
      Altitude<1000m, Correction Factor 1. <2000m, Correction Factor >0.92, <3000m; Correction Factor >0.84
      Alerts500  Event  Log
      Paralel OperationParallel Power Increase up to 16pcs.
      EPO (Emergency Power Off) Standard
      Isolation TransformerOptional
      Net Weight (without battery)
      285kg
      305kg
      310kg
      Dimensions (WxDxH)880x770x1660mm
      * under certain conditions
      * 3 Phase in/1 Phase Out Version is Available (10 to 30 kVA)
      Makelsan reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Makelsan products previously or subsequently sold. Makelsan does
      not guarantee the items of the accuracy and completeness.

       

    • Model
      Capacity
      160
      kVA
      200
      kVA
      Power Watt
      120 kW
      160
      kW
      Input
      Input Voltage Range 220/380VAC -15% +18% 3P+N+PE Optional 220/380VAC -37% +22% 3P+N+PE
      Input Power Factor At Full Load >0.99
      Input Frequency Range45 – 65 Hz (Selectable)
      RectifierIGBT
      THDi<%3
      Output
      Output Voltage Range220/380VAC, 230/400VAC and 240/415VAC 3 Phase + N ± 1%
      Recovery0% – 100% – 0% Load, Maximum Output Tolerance 5%, 1% Back to Band <40ms
      EfficencyUp to 93%, Eco Mode 98%
      Output Frequency Range50Hz ±0.5% Synchronous With the Network / 50Hz  ±0.01% Battery Mode
      Output THD Lineer Load <%2
      Non-lineer Load <%5
      Crest Factor3:1
      Overload CapacityAt 125% Load 10min, at 150% Load 1min
      Battery
      Quantity (12V DC VRLA)2×31
      Charge Value (C)Nominal 0,1 C, Adjustable
      Battery Power25% of The Device Power
      Internal BatteryNot Available
      Communication
      Communication PortRS232 Standart, RS485 ve SNMP Adapter Option
      Dry ContactOptional
      ProtocolSEC, TELNET
      Standards
      QualityISO 9001 – ISO 14001 – ISO 18001
      PerformanceEN62040 -3 (VFI-SS-111)
      EMC/LVDEN62040 – 2 / EN62040 -1 EN60950
      General
      Running TemperatureFor UPS 0°C~40°C For Battery 0°C~25°C
      Storage TemperatureFor UPS 15°C ~45°C For Batteries -10°C~60°C
      Protection ClassIP20
      ChassisAnti-Static Paint Protection
      Humidity0-95%
      Altitude<1000m, Correction Factor 1. <2000m, Correction Factor >0.92, <3000m; Correction Factor >0.84
      Alerts500  Event  Log
      Paralel OperationParallel Power Increase up to 16pcs.
      EPO (Emergency Power Off) Standard
      Isolation TransformerOptional
      Net Weight (without battery)
      475kg
      485kg
      Dimensions (WxDxH)1055x815x1905mm
      * under certain conditions
      * 3 Phase in/1 Phase Out Version is Available (10 to 30 kVA)
      Makelsan reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Makelsan products previously or subsequently sold. Makelsan does
      not guarantee the items of the accuracy and completeness.

       

    Solicită informații





    * câmpuri obligatorii

    Prin utilizarea acestui formular, ești de acord cu prelucrarea și stocarea datelor personale furnizate. Pentru a afla mai multe detalii, te rugăm să citești Politica de Confidențialitate.